Basically, the DSTATCOM system is comprised of three main parts: a Voltage Source Converter (VSC), a set of coupling reactors and a controller. The basic principle of a DSTATCOM installed in a power system is the generation of a controllable ac voltage source by a voltage source inverter (VSI) connected
Category: FACTS
TCSC is used to decrease or increase overall effective series transmission impedance from sending end to the receiving end so as to control the transmission of power and the current in the reactor can be controlled from zero to maximum by the method of firing delay angle. Closure of the
The D-STATCOM is basically one of the custom power devices. It is nothing but a STATCOM but used at the Distribution level. The D-STATCOM is a voltage or current source inverter based custom power device connected in shunt with the power system. It is connected near the load at the
The advantages of using FACTS devices in electrical transmission systems are described below. 1. MORE UTILIZATION OF EXISTING TRANSMISSION SYSTEM In all the countries, the power demand is increasing day by day to transfer the electrical power and controlling the load flow of the transmission system is very necessary this
The basic Thyristor Controlled Series Capacitor scheme was proposed in 1986 by Vithayathil with others as a method of “rapid adjustment of network impedance”. A TCSC can be defined as a capacitive reactance compensator which consists of a series capacitor bank shunted by a thyristor-controlled reactor in order to provide
STATCOM is a Static synchronous generator operated as a shunt-connected static VAR compensator whose capacitive or inductive output current can be controlled independent of the ac system voltage. STATCOM is one of the key FACTS Controllers. A STATCOM is a controlled reactive power source. It provides voltage support by generating
The shunt component is responsible for mitigating the power quality (PQ) problems caused by the consumer: poor power factor, load harmonic currents, load unbalance, DC offset, etc. The shunt active filter is responsible for power factor correction, compensation of load current harmonics and unbalances. It maintains constant average voltage across
Recent developments of FACTS research have led to a new device: the Interline Power Flow Controller (IPFC). This element consists of two (or more) series voltage source converter-based devices (SSSCs) installed in two (or more) lines and connected at their DC terminals. Thus, in addition to serially compensating the reactive
The FACTS technology is not represented by a single high-power controlling device, but it is a collection of all the controllers, these individually or in coordination with the others give the possibility to fast control one or more of the interdependent parameters that influence the operation of transmission networks. These