OPERATION OF THREE PHASE THREE WINDINGS UNIFIED POWER QUALITY CONDITIONER

The shunt component is responsible for mitigating the power quality (PQ) problems caused by the consumer: poor power factor, load harmonic currents, load unbalance, DC offset, etc. The shunt active filter is responsible for power factor correction, compensation of load current harmonics and unbalances. It maintains constant average voltage across the dc storage capacitor Cdc. The shunt part of UPQC consists of a VSI connected to the common dc storage capacitor Cdc on the dc side and on the ac side it is connected in parallel with the load through the shunt interface inductors LSH and a star-connected three-phase shunt coupling auto-transformer TSH. The shunt interface inductors LSH together with the shunt filter capacitors CSH are used to filter out the switching frequency harmonics produced by the shunt VSI. TSH is used for matching the network and VSI voltages.
The series component of UPQC is responsible for mitigation of supply side disturbances: voltage sags/swells, flicker, voltage unbalance and harmonics. It inserts voltages so as to maintain the load voltages at a desired level balanced and distortion free. And also series active filter is responsible for voltage compensation during supply side disturbances. The series part of the UPQC also consists of a VSI connected on the dc side to the same energy storage capacitor Cdc and on the ac side, it is connected in series with the feeder through the series low-pass filter (LPF) and three individual single-phase series coupling transformers TSE.

Comments

Popular posts from this blog

ADVANTAGES AND DISADVANTAGES OF CORONA

Corona has many advantages and disadvantages. In the correct design of a high voltage overhead line, a balance should be struck between the advantages and disadvantages. ADVANTAGES (i) Due to corona formation, the air surrounding the conductor becomes conducting and hence virtual diameter of the conductor is increased. The increased diameter reduces the electrostatic stresses between the conductors. (ii) Corona reduces the effects of transients produced by surges. DIS-ADVANTAGES (i) Corona is accompanied by a loss of energy. This affects the transmission efficiency of the line. (ii) Ozone is produced by corona and may cause corrosion of the conductor due to chemical action. (iii) The current drawn by the line due to corona is non-sinusoidal and hence non-sinusoidal voltage drop occurs in the line. This may cause inductive interference with neighboring communication lines.

ADVANTAGES OF PER UNIT SYSTEM

PER UNIT SYSTEM The per-unit system expressed the voltages, currents, powers, impedances, and other electrical quantities basis by the equation: Quantity per unit (pu) = Actual value/ Base value of quantity ADVANTAGES OF PER UNIT SYSTEM While performing calculations, referring quantities from one side of the transformer to the other side serious errors may be committed. This can be avoided by using per unit system. Voltages, currents and impedances expressed in per unit do not change when they are referred from one side of transformer to the other side. This is a great advantage. Per unit impedances of electrical equipment of similar type usually lie within a narrow range, when the equipment ratings are used as base values. Transformer connections do not affect the per unit values. Manufacturers usually specify the impedances of machines and transformers in per unit or percent of name plate ratings. Transformers can be replaced by their equivalent series impedances. ...

ABSOLUTE AND SECONDARY INSTRUMENTS

The various electrical instruments may, in a very broad sense, be divided into (i) Absolute Instruments (ii) Secondary Instruments. Absolute Instruments are those which give the value of the quantity to be measured, in terms of the constants of the instrument and their deflection only. No previous calibration or comparison is necessary in their case. The example of such an instrument is tangent galvanometer, which gives the value of current, in terms of the tangent of deflection produced by the current, the radius and number of turns of wire used and the horizontal component of earth’s field.  Secondary Instruments  are those, in which the value of electrical quantity to be measured can be determined from the deflection of the instruments, only when they have been pre-calibrated by comparison with an absolute instrument. Without calibration, the deflection of such instruments is meaningless. It is the secondary instruments, which are most generally used in ev...