Following are the minimum information and Data which to be shown on a transformer nameplate. The standards require the following information and data for transformers rated above 500 kVA. • Name of manufacturer • Serial number • year of manufacture • Number of phases • kVA or MVA rating •
Year: 2014
As the size and capacity of the transformer increased, the associated cooling arrangement become more powerful and sophisticated. So, by definition, the transformer cooling system is such arrangement for power transformers, which limits the generated heat into a safe value by means of proper dissipation of generated heat. Different cooling
The electrical winding and the magnetic core in a transformer are subject to a number of different forces during operation, for example. a) Expansion and contraction due to thermal cycling.b) Vibration.c) Local heating due to magnetic flux.d) Impact forces due to through fault current.e) Excessive heating over loading or inadequate
The main principle of operation of a transformer is mutual inductance between two circuits which is linked by a common magnetic flux. A basic transformer consists of two coils that are electrically separate and inductive, but are magnetically linked through a path of reluctance. The working principle of the transformer
There are three main parts of a power transformer. 1. Primary winding of transformer – which produces magnetic flux when it is connected to electrical source. 2. Magnetic Core of transformer – the magnetic flux produced by the primary winding, will pass through this low reluctance path linked with secondary
Power transformers need to be protected from damages caused by internal and external faults. Power transformer can be protected from the internal faults by Differential Relay. This task is performed by relay protection which detects the fault situation and gives command to the relevant circuit breaker(s) to disconnect the faulty
Two types of faults occur in power transformer i.e. external and internal electrical faults.External Faults in Power Transformer: (a) External Short – Circuit of Power Transformer: The short – circuit may occur in two or three phases of electrical power system. The level of fault current is always high enough.
POWER TRANSFORMER “A Power transformer is a static machine used for transforming power from one circuit to another circuit without changing Power and frequency”. Power transformers used between the generator and the distribution circuits, and these are usually rated at 500 KVA and above. Power systems typically consist of a
It is broadly classified into Conventional energy is in practice for long duration of time and well established technology is available to tap and use them. e.g. Coal, oil, natural gas, hydro power, nuclear power etc. Non-conventional energy source can be used with advantage for power generation as well as
The plasma chambers suspend the silicon and the phosphorus or boron molecules in a gaseous state. This mixture is pushed into a chamber which has electrodes at the top and bottom. When the electrodes are charged an electric field is produced between them. The electric field removes some of the