December 2014

POWER GENERATING SYSTEMS

Electrical power can be produced in many ways, including chemical reactions, heat, light, or mechanical energy. Most electrical power produced today is through hydroelectric plants and nuclear energy, and by burning coal, oil, or natural gas. Fossil fuel and nuclear-fission plants use steam turbines to deliver the mechanical energy required to rotate large three-phase generators, […]

POWER GENERATING SYSTEMS Read More »

AUXILIARY DEVICES OF SYNCHRONOUS GENERATOR

In addition to the basic components of a synchronous generator (the rotor, stator, and their windings), auxiliary devices are used to help maintain the machine’s operation within acceptable limits. These devices include the following: GOVERNOR The function of the governor is to control the mechanical power input to the generator. The control is via a

AUXILIARY DEVICES OF SYNCHRONOUS GENERATOR Read More »

HIGH VOLTAGE DC TRANSMISSION

High-voltage dc (HVDC) transmission offers several advantages over alternating current for long-distance power transmission and asynchronous interconnection between two ac systems, including the ability to precisely control the power flow without inadvertent loop flows that can occur in an interconnected ac system. HVDC transmission can be classified into one of three broad categories: • Back-to-back

HIGH VOLTAGE DC TRANSMISSION Read More »

BREAKER SCHEMES

The circuit breaker scheme used at a substation provides for varying degrees of reliability and maintainability on both the input and output sides. Each additional circuit breaker provides greater reliability and flexibility in maintaining the bus energized during a fault or during maintenance. However, the cost also increases with each circuit breaker. Hence, the selection

BREAKER SCHEMES Read More »

CONTROL AND SWITCHING SYSTEMS

Specialized hardware is necessary to interconnect the elements of a power-distribution system. Utility control and switching systems operate under demanding conditions, including high voltage and current levels, exposure to lightning discharges, and 24-hour-a-day use. For reliable performance, large margins of safety must be built into each element of the system. The primary control and switching

CONTROL AND SWITCHING SYSTEMS Read More »

SKIN EFFECT

The effective resistance offered by a conductor to high frequencies is considerably greater than the ohmic resistance measured with direct currents (dc). This is because of an action known as the skin effect, which causes the currents to be concentrated in certain parts of the conductor and leaves the remainder of the cross section to

SKIN EFFECT Read More »

ADVANTAGES OF INTERCONNECTED GRID SYSTEM

The connection of several generating stations in parallel is known as interconnected grid system. The various problems facing the power engineers are considerably reduced by interconnecting different power stations in parallel. Although interconnection of station involves extra cost, yet considering the benefits derived from such an arrangement, it is gaining much favor these days. Some of

ADVANTAGES OF INTERCONNECTED GRID SYSTEM Read More »