AUTOMATIC GENERATION CONTROLS (AGC)

Disturbances may also change the voltage at the generator’s terminals. In response, the generator’s automatic voltage regulating system will sense the change and adjust the generator’s field excitation, either up or down, to compensate.

Transient stability or instability considers that period immediately after a disturbance, usually before the generator’s governor and other control systems have a chance to operate. In all cases, the disturbance causes the generator angles to change automatically as they adjust to find a new stable operating point with respect to one another. In an unstable case, the angular separation between one generator or group of generators and another group keeps increasing. This type of instability happens so quickly, in a few seconds, that operator corrective action is impossible.



If stable conditions exist, the generator’s speed governor system, sensing the beginning of change in speed, will then react to either admit more mechanical energy into the rotor to regain its speed or to reduce the energy input to reduce the speed. Directives may also be received by the generator from the company or balancing area control center to adjust its scheduled output.

In addition to the measures noted to improve steady-state stability, other design measures available for selected disturbances to mitigate this type instability are:
  • Increasing the speed by which relays detect the fault and the speed by which circuit breakers operate to disconnect the faulted equipment sooner
  • Using dynamic braking resistors which, in the event of a fault, are automatically connected to the system near generators to reduce export from the generators
  • Fast valving systems on turbines allowing rapid reduction in the mechanical energy input to the turbine generator
  • Automatic generator tripping
  • Automatic load disconnection using under frequency or under voltage protective systems
  • Special transmission line tripping schemes
Dynamic instability refers to a condition in which the control systems of generators interact in such a way as to produce oscillations between generators or groups of generators that increase in magnitude and result in instability, that is, there is insufficient damping of the oscillations. These conditions can occur either in normal operation or after a disturbance.

Comments

Popular posts from this blog

ADVANTAGES AND DISADVANTAGES OF CORONA

Corona has many advantages and disadvantages. In the correct design of a high voltage overhead line, a balance should be struck between the advantages and disadvantages. ADVANTAGES (i) Due to corona formation, the air surrounding the conductor becomes conducting and hence virtual diameter of the conductor is increased. The increased diameter reduces the electrostatic stresses between the conductors. (ii) Corona reduces the effects of transients produced by surges. DIS-ADVANTAGES (i) Corona is accompanied by a loss of energy. This affects the transmission efficiency of the line. (ii) Ozone is produced by corona and may cause corrosion of the conductor due to chemical action. (iii) The current drawn by the line due to corona is non-sinusoidal and hence non-sinusoidal voltage drop occurs in the line. This may cause inductive interference with neighboring communication lines.

ADVANTAGES OF PER UNIT SYSTEM

PER UNIT SYSTEM The per-unit system expressed the voltages, currents, powers, impedances, and other electrical quantities basis by the equation: Quantity per unit (pu) = Actual value/ Base value of quantity ADVANTAGES OF PER UNIT SYSTEM While performing calculations, referring quantities from one side of the transformer to the other side serious errors may be committed. This can be avoided by using per unit system. Voltages, currents and impedances expressed in per unit do not change when they are referred from one side of transformer to the other side. This is a great advantage. Per unit impedances of electrical equipment of similar type usually lie within a narrow range, when the equipment ratings are used as base values. Transformer connections do not affect the per unit values. Manufacturers usually specify the impedances of machines and transformers in per unit or percent of name plate ratings. Transformers can be replaced by their equivalent series impedances. ...

ABSOLUTE AND SECONDARY INSTRUMENTS

The various electrical instruments may, in a very broad sense, be divided into (i) Absolute Instruments (ii) Secondary Instruments. Absolute Instruments are those which give the value of the quantity to be measured, in terms of the constants of the instrument and their deflection only. No previous calibration or comparison is necessary in their case. The example of such an instrument is tangent galvanometer, which gives the value of current, in terms of the tangent of deflection produced by the current, the radius and number of turns of wire used and the horizontal component of earth’s field.  Secondary Instruments  are those, in which the value of electrical quantity to be measured can be determined from the deflection of the instruments, only when they have been pre-calibrated by comparison with an absolute instrument. Without calibration, the deflection of such instruments is meaningless. It is the secondary instruments, which are most generally used in ev...