Author name: Engr. Aneel Kumar

SKIN EFFECT

The effective resistance offered by a conductor to high frequencies is considerably greater than the ohmic resistance measured with direct currents (dc). This is because of an action known as the skin effect, which causes the currents to be concentrated in certain parts of the conductor and leaves the remainder of the cross section to […]

SKIN EFFECT Read More »

ADVANTAGES OF INTERCONNECTED GRID SYSTEM

The connection of several generating stations in parallel is known as interconnected grid system. The various problems facing the power engineers are considerably reduced by interconnecting different power stations in parallel. Although interconnection of station involves extra cost, yet considering the benefits derived from such an arrangement, it is gaining much favor these days. Some of

ADVANTAGES OF INTERCONNECTED GRID SYSTEM Read More »

REQUIREMENTS OF SATISFACTORY ELECTRIC SUPPLY

The electric power system in general is 3-phase a.c. operating at a frequency of 50 Hz. The power station delivers power to consumers through its transmission and distribution systems. The power delivered must be characterized by constant or nearly constant voltage, dependability of service, balanced voltage, efficiency so as to give minimum annual cost, sinusoidal

REQUIREMENTS OF SATISFACTORY ELECTRIC SUPPLY Read More »

TYPES OF CONNECTION OF WIND TURBINE TO GRID

There are perhaps four distinct categories of wind power which should be discussed. These are 1. small, non-grid connected2. small, grid connected3. large, non-grid connected4. large, grid connected By small, we mean a size appropriate for an individual to own, up to a few tens of kilowatts. Large fers to utility scale. SMALL NON-GRID CONNECTED

TYPES OF CONNECTION OF WIND TURBINE TO GRID Read More »

SOURCES AND EFFECT OF UNBALANCE IN THREE PHASE POWER SYSTEM

SOURCES OF UNBALANCE Unbalance may generate due to the unequal drops in individual phase or unbalanced in three phase loading. Even it may happen due the source, load, improper grounding, etc. The main causes of voltage due to unbalance in power systems are • Unbalanced single-phase loading in a three-phase system: most of the domestic

SOURCES AND EFFECT OF UNBALANCE IN THREE PHASE POWER SYSTEM Read More »

WHY SHOULD ONLY AN ONLINE UPS BE USED WITH A STANDBY GENERATOR?

An online UPS accepts input power with relatively wide variations in voltage and frequency, a common occurrence in power produced by standby generators. The true on-line (double conversion) technology provided by an on-line UPS handles these variations by converting the input power from AC to DC and then converting DC to AC output power. Generators

WHY SHOULD ONLY AN ONLINE UPS BE USED WITH A STANDBY GENERATOR? Read More »