Steady State, Transient, and Sub-Transient Armature Reactions

Introduction

The armature reaction in synchronous generators plays a significant role in their performance and stability. This article examines the different states of armature reaction—steady state, transient, and sub-transient—and their impact on generator operation.

Steady State Armature Reaction

In the steady state, the armature reaction is constant and predictable, allowing for stable operation. This state is characterized by a consistent magnetic field interaction between the stator and rotor, ensuring reliable power generation under normal operating conditions.

Transient Armature Reaction

During transient states, such as sudden load changes or short circuits, the armature reaction becomes dynamic. This transient reaction involves temporary changes in the magnetic field, which can affect the generator's voltage and stability. Understanding transient reactions is crucial for designing protective measures and control systems.

Sub-Transient Armature Reaction

Sub-transient armature reaction occurs immediately following a disturbance, before the transient state is fully established. This reaction is characterized by rapid changes in the magnetic field and can significantly impact the generator's performance. Proper design and control strategies are necessary to mitigate the effects of sub-transient reactions.

Conclusion

The different states of armature reaction—steady state, transient, and sub-transient—highlight the complexity of synchronous generator operation. Understanding these reactions is essential for optimizing generator performance and ensuring stability under various operating conditions.

Comments

Popular posts from this blog

ADVANTAGES AND DISADVANTAGES OF CORONA

Corona has many advantages and disadvantages. In the correct design of a high voltage overhead line, a balance should be struck between the advantages and disadvantages. ADVANTAGES (i) Due to corona formation, the air surrounding the conductor becomes conducting and hence virtual diameter of the conductor is increased. The increased diameter reduces the electrostatic stresses between the conductors. (ii) Corona reduces the effects of transients produced by surges. DIS-ADVANTAGES (i) Corona is accompanied by a loss of energy. This affects the transmission efficiency of the line. (ii) Ozone is produced by corona and may cause corrosion of the conductor due to chemical action. (iii) The current drawn by the line due to corona is non-sinusoidal and hence non-sinusoidal voltage drop occurs in the line. This may cause inductive interference with neighboring communication lines.

ADVANTAGES OF PER UNIT SYSTEM

PER UNIT SYSTEM The per-unit system expressed the voltages, currents, powers, impedances, and other electrical quantities basis by the equation: Quantity per unit (pu) = Actual value/ Base value of quantity ADVANTAGES OF PER UNIT SYSTEM While performing calculations, referring quantities from one side of the transformer to the other side serious errors may be committed. This can be avoided by using per unit system. Voltages, currents and impedances expressed in per unit do not change when they are referred from one side of transformer to the other side. This is a great advantage. Per unit impedances of electrical equipment of similar type usually lie within a narrow range, when the equipment ratings are used as base values. Transformer connections do not affect the per unit values. Manufacturers usually specify the impedances of machines and transformers in per unit or percent of name plate ratings. Transformers can be replaced by their equivalent series impedances. ...

ABSOLUTE AND SECONDARY INSTRUMENTS

The various electrical instruments may, in a very broad sense, be divided into (i) Absolute Instruments (ii) Secondary Instruments. Absolute Instruments are those which give the value of the quantity to be measured, in terms of the constants of the instrument and their deflection only. No previous calibration or comparison is necessary in their case. The example of such an instrument is tangent galvanometer, which gives the value of current, in terms of the tangent of deflection produced by the current, the radius and number of turns of wire used and the horizontal component of earth’s field.  Secondary Instruments  are those, in which the value of electrical quantity to be measured can be determined from the deflection of the instruments, only when they have been pre-calibrated by comparison with an absolute instrument. Without calibration, the deflection of such instruments is meaningless. It is the secondary instruments, which are most generally used in ev...