Since the development of interconnection of large electric power systems, it has been the spontaneous system oscillations at very low frequencies in the range of 0.2–3.0 Hz. After starts, it would continue for a long period of time. In certain cases, it continues to develop causing system separation due to the lack of damping of the mechanical modes. In the past three decades, Power System Stabilizers (PSSs) have been extensively used to increase the system damping for low frequency oscillations. The power utility worldwide is currently implementing PSSs as effective excitation controllers to enhance the system stability. Yet, some problems are experienced with PSSs over the years of operation. Some of these were limited to the capability of PSS, due to damping in local modes and not in the inter-area modes of oscillations.
In accumulation, it can cause huge variations in the voltage profile under severe disturbances and they may even result in leading power factor operation and losing system stability. It has necessitate a review of the traditional power system concepts and practices to achieve a larger stability margin, better operational flexibility, and better utilization of existing power systems. Flexible AC transmission systems (FACTS) have gained a great interest during the last few years, due to the recent techniques in power electronics. FACTS devices are mainly used for solving various power system steady state control problems such as voltage regulation, transfer capability enhancement and power flow control. As supplementary functions, damping the inter-area modes and enhancing power system stability using FACTS controllers have been extensively studied and investigate. Generally, it is not cost-effective to install FACTS devices for the sole purpose of power system stability enhancement.

Comments

Popular posts from this blog

ADVANTAGES AND DISADVANTAGES OF CORONA

Corona has many advantages and disadvantages. In the correct design of a high voltage overhead line, a balance should be struck between the advantages and disadvantages. ADVANTAGES (i) Due to corona formation, the air surrounding the conductor becomes conducting and hence virtual diameter of the conductor is increased. The increased diameter reduces the electrostatic stresses between the conductors. (ii) Corona reduces the effects of transients produced by surges. DIS-ADVANTAGES (i) Corona is accompanied by a loss of energy. This affects the transmission efficiency of the line. (ii) Ozone is produced by corona and may cause corrosion of the conductor due to chemical action. (iii) The current drawn by the line due to corona is non-sinusoidal and hence non-sinusoidal voltage drop occurs in the line. This may cause inductive interference with neighboring communication lines.

ADVANTAGES OF PER UNIT SYSTEM

PER UNIT SYSTEM The per-unit system expressed the voltages, currents, powers, impedances, and other electrical quantities basis by the equation: Quantity per unit (pu) = Actual value/ Base value of quantity ADVANTAGES OF PER UNIT SYSTEM While performing calculations, referring quantities from one side of the transformer to the other side serious errors may be committed. This can be avoided by using per unit system. Voltages, currents and impedances expressed in per unit do not change when they are referred from one side of transformer to the other side. This is a great advantage. Per unit impedances of electrical equipment of similar type usually lie within a narrow range, when the equipment ratings are used as base values. Transformer connections do not affect the per unit values. Manufacturers usually specify the impedances of machines and transformers in per unit or percent of name plate ratings. Transformers can be replaced by their equivalent series impedances. ...

ABSOLUTE AND SECONDARY INSTRUMENTS

The various electrical instruments may, in a very broad sense, be divided into (i) Absolute Instruments (ii) Secondary Instruments. Absolute Instruments are those which give the value of the quantity to be measured, in terms of the constants of the instrument and their deflection only. No previous calibration or comparison is necessary in their case. The example of such an instrument is tangent galvanometer, which gives the value of current, in terms of the tangent of deflection produced by the current, the radius and number of turns of wire used and the horizontal component of earth’s field.  Secondary Instruments  are those, in which the value of electrical quantity to be measured can be determined from the deflection of the instruments, only when they have been pre-calibrated by comparison with an absolute instrument. Without calibration, the deflection of such instruments is meaningless. It is the secondary instruments, which are most generally used in ev...