Skip to main content

VAR COMPENSATION

VAR compensation is defined as the management of reactive power to improve the performance of ac power systems; maximizing stability by increasing flow of active power. Few Problems forced while reactive power compensation which are:

1. Load compensation
2. Voltage support

LOAD COMPENSATION OBJECTIVES: are to increase the value of the system power factor to balance the real power drawn from the ac supply, compensate voltage regulation and to eliminate current harmonic components produced by large and fluctuating non-linear industries loads.

VOLTAGE SUPPORT OBJECTIVES: It’s generally required to reduce voltage fluctuations at a given terminal of a transmission line.
VAR compensation helps to maintain a substantially flat voltage profile at all levels of power transmission improves HVDC conversion terminal performance increases transmission efficiency ,controls steady state and temporary over-voltage and can avoid disastrous blackout.

Series and shunt VAR compensation are used to modify the natural electrical characteristic of ac power system. Series compensation modifies the transmission or distribution system parameters while shunt compensation changes the equivalent impedance of the load.

Earlier, rotating synchronous condensers and fixed or mechanically switched capacitors or inductors have been used for reactive power compensation. Now a days static VAR compensators employing thyristor switched capacitors and thyristor controlled reactor to provide or absorb the required reactive power have been developed. Use of self-commutated PWM convertors with appropriate control scheme permits the implementation of static compensators capable of generating or absorbing reactive current components with faster time response.

Comments

Popular posts from this blog

ADVANTAGES AND DISADVANTAGES OF CORONA

Corona has many advantages and disadvantages. In the correct design of a high voltage overhead line, a balance should be struck between the advantages and disadvantages. ADVANTAGES (i) Due to corona formation, the air surrounding the conductor becomes conducting and hence virtual diameter of the conductor is increased. The increased diameter reduces the electrostatic stresses between the conductors. (ii) Corona reduces the effects of transients produced by surges. DIS-ADVANTAGES (i) Corona is accompanied by a loss of energy. This affects the transmission efficiency of the line. (ii) Ozone is produced by corona and may cause corrosion of the conductor due to chemical action. (iii) The current drawn by the line due to corona is non-sinusoidal and hence non-sinusoidal voltage drop occurs in the line. This may cause inductive interference with neighboring communication lines.

ADVANTAGES OF PER UNIT SYSTEM

PER UNIT SYSTEM The per-unit system expressed the voltages, currents, powers, impedances, and other electrical quantities basis by the equation: Quantity per unit (pu) = Actual value/ Base value of quantity ADVANTAGES OF PER UNIT SYSTEM While performing calculations, referring quantities from one side of the transformer to the other side serious errors may be committed. This can be avoided by using per unit system. Voltages, currents and impedances expressed in per unit do not change when they are referred from one side of transformer to the other side. This is a great advantage. Per unit impedances of electrical equipment of similar type usually lie within a narrow range, when the equipment ratings are used as base values. Transformer connections do not affect the per unit values. Manufacturers usually specify the impedances of machines and transformers in per unit or percent of name plate ratings. Transformers can be replaced by their equivalent series impedances. ...

ABSOLUTE AND SECONDARY INSTRUMENTS

The various electrical instruments may, in a very broad sense, be divided into (i) Absolute Instruments (ii) Secondary Instruments. Absolute Instruments are those which give the value of the quantity to be measured, in terms of the constants of the instrument and their deflection only. No previous calibration or comparison is necessary in their case. The example of such an instrument is tangent galvanometer, which gives the value of current, in terms of the tangent of deflection produced by the current, the radius and number of turns of wire used and the horizontal component of earth’s field.  Secondary Instruments  are those, in which the value of electrical quantity to be measured can be determined from the deflection of the instruments, only when they have been pre-calibrated by comparison with an absolute instrument. Without calibration, the deflection of such instruments is meaningless. It is the secondary instruments, which are most generally used in ev...