THE COMPONENTS OF A GRID TIED PV SYSTEM

A PV System includes:

1. PV ARRAY

Multiple PV panels installed together are called a PV array. Mounting arrays to rooftops is most common, yet they can also be located on a pole, a ground mounted rack, parking area shade covers, window awnings, etc. The PV array produces Direct Current (DC) power.

2. DC DISCONNECT

The DC Disconnect is a safety device that, when manually opened, stops power running from the array to the rest of the system. The DC disconnect is used during system installation and anytime your contractor needs to work on the system.

3. DC/AC INVERTER

The PV array produces DC electricity, however, we use Alternating Current (AC) electricity in our buildings and power grid. The Inverter converts the DC power to AC power.

4. AC DISCONNECT

The AC Disconnect is another safety device and is often incorporated into the Inverter. Seattle City Light does not require an AC Disconnect on most small residential systems. (For details on this exemption, contact your Electric Service Representative.

PRODUCTION METER

The Production Meter measures the energy output (in kilowatt-hours, kWh) from your system and is used to record the amount of electricity generated. This component is not critical to power generation, but is necessary in order to take advantage of Washington State’s Production Incentive Program.

6. BUILDING BREAKER BOX AND STANDARD UTILITY METER

Also called your building’s circuit panel or electrical service panel, the Breaker Box is where the power from the PV System enters the building. If the building is using electricity, the PV-produced electricity will be used first. If the building needs more electricity than the PV System is producing, utility grid power is automatically pulled into the building. When the PV System produces more electricity than is needed, the excess flows back out to the utility, spinning your utility billing meter backwards in the process. You earn credit for the excess power produced and can use that credit when the system is not producing energy. This process is referred to as “net metering.”


Comments

Popular posts from this blog

ADVANTAGES AND DISADVANTAGES OF CORONA

Corona has many advantages and disadvantages. In the correct design of a high voltage overhead line, a balance should be struck between the advantages and disadvantages. ADVANTAGES (i) Due to corona formation, the air surrounding the conductor becomes conducting and hence virtual diameter of the conductor is increased. The increased diameter reduces the electrostatic stresses between the conductors. (ii) Corona reduces the effects of transients produced by surges. DIS-ADVANTAGES (i) Corona is accompanied by a loss of energy. This affects the transmission efficiency of the line. (ii) Ozone is produced by corona and may cause corrosion of the conductor due to chemical action. (iii) The current drawn by the line due to corona is non-sinusoidal and hence non-sinusoidal voltage drop occurs in the line. This may cause inductive interference with neighboring communication lines.

ADVANTAGES OF PER UNIT SYSTEM

PER UNIT SYSTEM The per-unit system expressed the voltages, currents, powers, impedances, and other electrical quantities basis by the equation: Quantity per unit (pu) = Actual value/ Base value of quantity ADVANTAGES OF PER UNIT SYSTEM While performing calculations, referring quantities from one side of the transformer to the other side serious errors may be committed. This can be avoided by using per unit system. Voltages, currents and impedances expressed in per unit do not change when they are referred from one side of transformer to the other side. This is a great advantage. Per unit impedances of electrical equipment of similar type usually lie within a narrow range, when the equipment ratings are used as base values. Transformer connections do not affect the per unit values. Manufacturers usually specify the impedances of machines and transformers in per unit or percent of name plate ratings. Transformers can be replaced by their equivalent series impedances. ...

ABSOLUTE AND SECONDARY INSTRUMENTS

The various electrical instruments may, in a very broad sense, be divided into (i) Absolute Instruments (ii) Secondary Instruments. Absolute Instruments are those which give the value of the quantity to be measured, in terms of the constants of the instrument and their deflection only. No previous calibration or comparison is necessary in their case. The example of such an instrument is tangent galvanometer, which gives the value of current, in terms of the tangent of deflection produced by the current, the radius and number of turns of wire used and the horizontal component of earth’s field.  Secondary Instruments  are those, in which the value of electrical quantity to be measured can be determined from the deflection of the instruments, only when they have been pre-calibrated by comparison with an absolute instrument. Without calibration, the deflection of such instruments is meaningless. It is the secondary instruments, which are most generally used in ev...